Network Reactance; Short Circuit Current; 400 A Load; Dxn - ABB DCS 500B Description

Software for thyristor power converter
Hide thumbs Also See for DCS 500B:
Table of Contents

Advertisement

Functional Software description
Network reac-
tance
Short Circuit Cur-
rent

400 A load

600 A load

DXN

46
X k = 2 * π * 50 Hz * (48.85 µH + 12.5 µH)
= 0.019274 Ω
I k = √2 * U / (2 * X k ) = 13941.33 A
Let´s calculate what will happen when DC-drive takes 400 A and β-
limit is set to 165°.
I d / I k = 400 A / 13941.33 A = 0.0287
cos 165° = -0.966
cos (α - u) = cos α - I d / I k = -0.9946
arc cos ( -0.9946) = 174° == > OK
Same with 600 A current:
I d / I k = 0.043
cos 165° = -1.009
cos (α - u) = cos α - I d / I k = -1.009
arc cos ( -1.009) = unspecified == > NOT OK, slip over
The DXN is proportional network short circuit voltage and it is de-
fined by using the converter nominal current.
The purpose of DXN is to prevent the slip over of the thyristor
bridge by changing the β-limit proportionally to the converter cur-
rent, if the network is "weak". DXN is calculated:
2 * Xk * I CONV A
DXN (414) =
Parameter value for DXN (414) in this example is 43 = 4.3 %.
Scale: 1 = 0.1 %.
* 1000
2 * U SUPPLY
DCS 500 Software Description

Hide quick links:

Advertisement

Table of Contents
loading