ABB DCS 500B Description page 215

Software for thyristor power converter
Hide thumbs Also See for DCS 500B:
Table of Contents

Advertisement

CUR,FLX,VLT 100%
Signal of CONSTANTS-function block
Value which corresponds to nominal positive current, flux and voltage = 4095.
12512
FB_O: I2
SC: -
CUR,FLX,VLT -100%
Signal of CONSTANTS-function block
Value which corresponds to nominal negative current, flux and voltage = -4096.
12513
FB_O: I2
SC: -
SPEED:
100%
Signal of CONSTANTS-function block
Value which corresponds to nominal positive speed = 20000.
12514
FB_O: I2
SC: -
SPEED:
-100%
Signal of CONSTANTS-function block
Value which corresponds to nominal negative speed = -20000.
12515
FB_O: I2
SC: -
SIG1(SPEED REF)
Signal of FREE_SIGNALS-function block
This block is containing signals which can be set by the CMT or panel.
Value which can be used to give a speed reference. Before the drive will follow this
reference, it has to be connected to the speed reference input ERR.[IN] (2001).
12516
FB_O: I2
SC: -
SIG2(SPEED STEP)
Signal of FREE_SIGNALS-function block
This block is containing signals which can be set by the CMT or panel.
Value which can be used to give a speed step. Before the drive will follow this step, it has
to be connected to the speed step input ERR.[STEP] (2002).
12517
FB_O: I2
SC: -
SIG3(TORQ. REF A)
Signal of FREE_SIGNALS-function block
This block is containing signals which can be set by the CMT or panel.
Value which can be used to give a torque reference. Before the drive will follow this
reference, it has to be connected to the torque reference input SEL1.[TREF_A] (2401).
12518
FB_O: I2
SC: -
SIG4(TORQ. REF B)
Signal of FREE_SIGNALS-function block
This block is containing signals which can be set by the CMT or panel.
Value which can be used to give a torque reference. Before the drive will follow this
reference, it has to be connected to the torque reference input SEL1.[TREF_B] (2404).
12519
FB_O: I2
SC: -
SIG5(TORQUE STEP)
Signal of FREE_SIGNALS-function block
This block is containing signals which can be set by the CMT or panel.
Value which can be used to give a torque step. Before the drive will follow this step, it has
to be connected to the torque step input SEL2.[TORQ_STEP] (2409).
12520
FB_O: I2
SC: -
HL: 4095
LL: 4095
HL: -4095
LL: -4095
HL: 20000
LL: 20000
HL: -20000
LL: -20000
HL: 30000
LL: -30000
HL: 30000
LL: -30000
HL: 30000
LL: -30000
HL: 30000
LL: -30000
HL: 30000
LL: -30000
DCS500 Pin and Parameter list
( S2,S16/16 )
D: 4095
U: -
( S2,S16/16 )
D: -4096
U: -
( S2,S16/16 )
D: 20000
U: -
( S2,S16/16 )
D: -20000
U: -
( S2,S16/16 )
D: 0
U: -
( S2,S16/16 )
D: 0
U: -
( S2,S16/16 )
D: 0
U: -
( S2,S16/16 )
D: 0
U: -
( S2,S16/16 )
D: 0
U: -
A 111

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents