Group 119: Reference Sources - ABB DCS 500B Description

Software for thyristor power converter
Hide thumbs Also See for DCS 500B:
Table of Contents

Advertisement

Group 119: REFERENCE SOURCES

CONST_REF:OUT
Signal of CONST_REF-function block
Selected constant speed reference.
11901
FB_O: I2
CONST_REF:ACT
Signal of CONST_REF-function block
Signal which is set to TRUE when one of the ACT-inputs is active.
11902
FB_O: B
REF_SEL:OUT
Signal of REF_SEL-function block
Selected speed reference which is usually connected to the ramp generator input.
11903
FB_O: I2
SOFT_POT:OUT
Signal of SOFT_POT-function block
Speed reference from the software potentiometer.
11904
FB_O: I2
SOFT_POT:ACT
Signal of SOFT_POT-function block
Signal which is set to TRUE if either input SOFTPOT.[INCR] (1918) or SOFTPOT.[DECR]
(1919) is active.
11905
FB_O: B
SC: SPEED
HL: -
SC: BO
HL: -
SC: SPEED
HL: -
SC: SPEED
HL: -
SC: BO
HL: -
DCS500 Pin and Parameter list
( S4/16 )
LL: -
D: -
( S4/16 )
LL: -
D: -
LL: -
D: -
LL: -
D: -
LL: -
D: -
U: rpm
U: -
( S4/16 )
U: rpm
( S4/16 )
U: rpm
( S4/16 )
U: -