DECEL2
Parameter of RAMP GENERATOR-function block.
The time in which the drive will decelerate from nominal speed to zero speed.
1712
FB_P: I2
SC: 0.1
SMOOTH2
Parameter of RAMP GENERATOR-function block.
The speed ramp output softening time (S-RAMP function).
The total time how long the softening function will last.
1713
FB_P: I2
SC: 1
EMESTOP_RAMP
Parameter of RAMP GENERATOR-function block.
The time in which the drive will decelerate from nominal speed to zero speed in
emergency stop situation.
1714
FB_P: I2
SC: 0.1
SPEEDMAX
Parameter of RAMP GENERATOR-function block.
Positive limit for speed reference.
1715
FB_P: I2
SC: SPEED
SPEEDMIN
Parameter of RAMP GENERATOR-function block.
Negative limit for speed reference.
1716
FB_P: I2
SC: SPEED
STARTSEL
Parameter of RAMP GENERATOR-function block.
Start-function when the motor is rotating
0 = START_FROM_0
1 = FLYING_START
1717
FB_P: E2
SC: -
ACC_COMP.MODE
Parameter of RAMP GENERATOR-function block.
Acceleration compensation function
0 = DISABLED
1 = ENABLED.
1718
FB_P: E2
SC: -
ACC_COMP.TRMIN
Parameter of RAMP GENERATOR-function block.
The time in which the drive will accelerate from zero speed to the maximum speed using
nominal torque (T N ) of the motor.
1719
FB_P: I2
SC: 0.1
RAMP.[SPEED_SET]
Input of RAMP GENERATOR-function block.
Set ramp output to this input with signal RAMP.[FOLL_ACT] (1705)
1720
FB_I: C4
SC: SPEED
HL: 30000
LL: 1
HL: 20000
LL: 0
HL: 30000
LL: 1
HL: 30000
LL: 0
HL: 0
LL: -30000
(ramp output = 0 at start)
(ramp output = actual speed at start.)
HL: 1
LL: 0
HL: 1
LL: 0
HL: 32767
LL: 0
HL: 19999
LL: 0
DCS500 Pin and Parameter list
( S4/16 )
D: 100
U: s
( S4/16 )
D: 0
U: ms
( S4/16 )
D: 200
U: s
( S4/16 )
D: 20000
U: rpm
( S4/16 )
D: -20000
U: rpm
( S4/16 )
D: 0
U: -
( S4/16 )
D: 0
U: -
( S4/16 )
D: 0
U: s
( S4/16 )
D: 12102
U: -
A 47