Identification of
the Converter
Software version
Identification of
the Field Exciter
Software version
DCS 500 Software Description
Parameter values will be saved by means of the parameter
BACKUP STORE MODE (11202). When the action is finished af-
ter writing or reading of parameters the mode is changed to 0
[NONE].
BACKUPSTORE MODE:
0 = [NONE]
1 = [SAVE MOT1 SET]
2 = [SAVE MOT2 SET]
3 = [FACTORY SET VALUE] default values are restored to the RAM
4 = [SELECT MOT1 SET]
5 = [SELECT MOT2 SET]
The version of the software can be identified in two ways:
-
software version is printed on the label which is located on the
memory circuits D33.
-
the signal CNT SW VERSION (11218) indicates the converter
program version.
VERSION
(226 = 1. version SDCS-CON-2)
(227 = 2. version)
DCS500
Figure 3
Identification labels of memory circuit D33
If a field exciter module SDCS-FEX-2 or DCF 503/4 (SDCS-
FEX-3x) is used the version of the field exciter software can be
identified in two ways:
-
software version is printed on a label on the micro controller of
the field supply unit SDCS-FEX-2 or DCF 503/4
-
the signal FEXC1 SW VERSION (11220) indicates the con-
verter program version.
when two field exciter units are installed in the drive, the pro-
gram version of the second unit can be read from signal FEXC2
SW VERSION (11221).
All the parameters of two-phase field exciter units are stored in the
FPROM memory circuit (D35) of the converter.
Functional Software description
no backup
save motor set 1 to FPROM memory.
save motor set 2 to FPROM memory.
memory
read motor set 1 from the FPROM memory
read motor set 2 from the FPROM memory
DC21.226