Signals Of Dcs 500 - ABB DCS 500B Description

Software for thyristor power converter
Hide thumbs Also See for DCS 500B:
Table of Contents

Advertisement

Signals of DCS 500

DCS/DCF500B signals are divided to several different signal groups. Signals of a certain group
belong to the same functional part of the control program. Maximum number of signals in one
group is 99.
Every signal is described using the same structure, which is shown by their basics below:
Name
Signal of {standard function block} function block
Explanation
index
data type
Name
is given in the same format as it is seen on the panel.
Sig
mentiones the name of the function block using this signal; at the end of this
line the page of the software diagrams available at the end of the System
Description is given; at some signals the software version is named this
signal is available for the first time
Expl
description in verbal form
Index
of a signal contains a group number and an element number. Last two digits
are the element number and other numbers before them form the group
number:
10101
11401
Data type
is given with a short code:
FB_O:
S:
I2
E2
PB
B
U2
Scaling factor
see table for parameters
Maximum
values are given as internal values for those signals which can be modified
by user.
Minimum
values are given as internal values for those signals which can be modified
by user.
Default
not used for signals
Unit
is given for signals which have an unit.
Example:
The signal which is giving the actual motor voltage has following description:
U_ARM_ACT
Signal of SETTINGS-function block.
Actual voltage of the motor. Scaling based on signal U_NET_DC_NOM
10505
FB_O: I2
Name
U_ARM_ACT
Sig
will be found at the SETTINGS function block, which is shown on the
software diagrams on page 2 out of 16
Expl
description in verbal form
Index
signal group = 105, element = 05
Data type
FB_O:
I2
Scaling factor
as for VOLT
Maximum
not available
Minimum
not available
Default
not available
Unit
is Volt;
scal. factor
maximum
=> signal group = 101, element = 01
=> signal group = 114, element = 01.
Output of a function block
Signal
16-bit signed integer
Selection signal
packed Boolean value
Boolean value
16-bit unsigned integer
SC: VOLT
HL: -
Output of a function block
16-bit signed integer
DCS500 Pin and Parameter list
(S11/16 ).
minimum
default
LL: -
D: -
unit
( S2/16 )
U: V
A 7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents