10. Maintenance
10.1. Preventive maintenance table
Carry out when the maintenance indicator light of the GNM 6080 is ON.
Sub-assembly
Nozzle support
O-ring
(JR/JP)
Seal cartridge
O-ring (Seal cartridge )
O-ring chemically inert
Barrel
O-ring FEP viton
O-ring chemically inert
O-ring chemically inert
O-ring chemically inert
O-ring (electrical connector)
O-ring (handle base))
Handle
O-ring (air nipple)
O-ring - chemically inert (outer of
valve)
Air valve
O-ring - chemically inert (inner of
valve)
Sealing ring
WARNING : (*): As soon as one of both terms is reached.
Index revision : C - March 2016
Description
29
Part
Qty
number
J3STKL094
1
910014338
1
J3STKL005
1
J3STKL032
1
J2FENV435
1
J3STKL078
1
J3STKL002
1
J3STKL019
1
160000041
1
160000067
1
J2FTCF018
1
J3STKL018
1
J3STKL005
1
J3STKL032
1
900010256
1
Minimum
replacement
frequency
3 months
6 months or 500.000
operations (*)
3 months
6 months
12 months
12 months
12 months
12 months
12 months
12 months
12 months
12 months
12 months
12 months
12 months
7105