Advertisement

3.2. GNM 6080 Control module

The GNM 6080 control module allows the display of the parameters of use as well as their adjustments.
11
10
9
10
11
12
13
Temperature fault : The temperature fault forces the indicator lights (Item11 and 12). As
soon as the temperature decrease under the minimum, the temperature indicator light (Item
11) goes out and the operator can delete the fault by pressing on the button «Reset of faults»
(Item 3).
Control module fault: this fault collects all the internal faults of the control module. If this
fault can not resetted, the problem requires the intervention of the repair department , contact
Sames Technologies.
Index revision : C - March 2016
12
13
Front face of the GNM 6080 control module
1
Maintenance indicator light
2
Indicator light of high voltage fault
3
Reset of faults
4
Display of setpoint of high voltage
5
Increase of the setpoint voltage
6
Bargraph of the current consumption
7
Indicator lights of active preset memory
8
Selection of the active memory
9
Bargraph of the voltage
Decrease of the setpoint voltage
Indicator light of temperature fault
Indicator light of control module fault
Indicator light of low voltage cable
1
13
2
3
4
5
6
7
8
7105