• The floor on which the operator works must be dissipator (bare concrete or metal duckboard).
Never use an insulating floor covering. In area potentially explosive, the assemblies of grounds
have to be dissipators according to the standard EN 61340-4-1.
• Naked flames, glowing objects or a devices likely to produce sparks (other than the atomizer) must
not be used inside the booth.
The storage of inflammable products, or vessels that have contained them, close to the booth or
in front of the doors is prohibited.
• Pots and tubs containing paint or solvent must always be closed after use.
• The paint supply pump used must have a maximum ratio of 1:1 and the pump air supply must be
fitted with a safety valve limiting the pressure to 6.5 bar maximum.
• In the explosive area, it is forbidden to use any non-certified electrical or non-electrical equipment
such as electronic extension leads, multiple socket adapters, switches, etc.

2.3. Operating rules

• The ventilation system must be checked on a daily basis to ensure it is working properly.
• Performance checks must be carried out on the extraction control system once a week.
• Before starting to spray, check that the nozzle/tip and air cap are fitted to the gun and that the air cap
ring is fully tightened.
• All metal parts of the booth and parts to be painted must be correctly grounded. Ground resistance
must be less than or equal to 1MΩ (measurement voltage 500 V). This resistance value must be
regularly checked.
• The operator must wear dissipator shoes according Standard EN 61340-4-3 and hold the
NANOGUN-MV spray gun bare-handed or with gloves that are either dissipators or specially
adapted to allow direct contact between the handle and the operator's hand. Shoes intended to be
worn by the operator have to be in accordance with the standard ISO 20344. The measured
insulating resistance does not have to exceed 100MΩ.
• Protective clothings intended to be worn, including gloves, have to be in accordance with the
standard EN 1149-5. The measured insulating resistance does not have to exceed 100MΩ.
• The operator must also wear ear defenders when using NANOGUN-MV spray guns
15).
• Ensure that anyone who enters the spraying area is wearing dissipator shoes or is otherwise
grounded.
• Never throw or drop deliberately the electrostatic spray gun. Dropping the gun could damage the
high voltage generator. After a drop, it is advised to verify the functioning of the pistol out off zone
before its re-use.
• Never point the spray gun towards a person.
• Check the spray gun at least 1 time a week.
• Never use the apparatus in the following situations:
1 If you notice an air leak from the spray gun when the trigger is released.
2 If the spray gun electrical connector catch is not held securely in place with two safety screws.
3 If the spray gun barrel, handle show signs of an impact that may have deteriorated the air-
tightness of internal components.
• The manual electrostatic projection equipment must be exploited only if it is in a perfect state. A
damaged equipment must be immediately removed from the installation and must be repaired.
The worn out components must be immediately replaced.
• Use paints whose flash point is at least 15°C higher than the ambient temperature.
• Follow the precautions specified for the paints and solvents used (e.g. wear a mask etc.).
• Close and dump the air and paint supply before leaving the device shut down for an extended
period.
• Check the paint hose is in good condition before starting to operate the device.
• The electropneumatic coupling, held in place by two safety screws
DISCONNECTED IN A POTENTIALLY EXPLOSIVE ATMOSPHERE.
• If any of the following elements are damaged, all operations with the device must be stopped:
barrel, handle, electropneumatic coupling, air cap or air cap ring.