10.11. High voltage cascade

• Step 1: Remove the trigger
• Step 2: Loosen the 4 screws fastening the barrel
on the handle with a 2mm Phillips screwdriver.
• Step 3: Unscrew, manually or with a small flat
pliers, the three connection wires of the high
voltage unit, pull carefully the contacts towards
the back.
• Step.4: Remove the high voltage contact in front
of the barrel
(see § 10.5 page
high voltage unit.
WARNING : Attention with the colors (terminal 1:
black, terminal 2: green, terminal 3: pink).
To reassemble, follow the steps in reverse order.
Replace the high-voltage cascade. Coat the cascade with red dielectric lubricant (P/N #
H1GSYN037) then insert it into its housing.
Push the cascade fully into the barrel. Connect the three wires and tighten the screws. Check the wear
of the o-rings, replace if necessary.
Index revision : C - March 2016
(see § 10.8 page
36), remove the paint needle.
34). Withdraw the