Health And Safety Instructions; Regulations; Installation Rules - Sames NANOGUN-MV LR User Manual

Table of Contents

Advertisement

2. Health and Safety Instructions

WARNING : This equipment may become a safety hazard if it is not operated, disassembled and
reassembled in accordance with the instructions given in this manual and in any
European Standard or national safety regulations in force.
The warning notice summarizing the safety rules (procedures and precautions) laid
out in this instruction manual must be clearly displayed in the area of the spraying
workstation.
WARNING : Equipment performance is only guaranteed if original spare parts distributed by
SAMES Technologies are used.

2.1. Regulations

The NANOGUN-MV spray gun must always be used according to the requirements stipulated in the
standards and regulations in force concerning painting and clear coat methods (see Standards and
Directives EN 50.053 part 1 ISO 12100, EN 1953 and 99/92/CE).
In Canada, the installation has to be in compliance with the code " electrical C22.1 Canadian code, part
I, standard safety for electrical installations ".
In the USA, the installation has to be in compliance with the code " NFPA 70: National Electrical Code ".
The Pollution Degree Rating of the NANOGUN-MV is "Pollution Degree 2" following IEC-664-1 standard
Pollution Degree 2: Normally only non-conductive pollution occurs. Temporary conductivity caused by
condensation is to be expected.
WARNING : Before any use of the NANOGUN-MV spray gun, check that all operators
• have previously been trained by the company Sames Technologies, or by their distributors
registered by them for this purpose.
• have read and understood the user manual and all rules for installation and operation, as listed
below.
It is the responsibility of the operator's workshop manager to ensure these two points and it is
also his responsibility to make sure that all operators have read and understood the user
manuals for any peripheral electrical equipment present in the spraying area.

2.2. Installation rules

• The manual projection electrostatic material must be used only in projection area according to the
standard EN 12215 or in equivalent conditions of ventilation.
• The control module must not be installed where there is a potential explosion risk.
• It must be impossible to start up the control module before the spray booth air extraction system
is in operation.
• The control module must be properly connected to the ground terminal on the device.
• The paint (or solvent) pump and tank must be connected to a ground terminal on the device.
• All metal parts of the apparatus (paint pumps, containers, stools, turntables, etc.) less than three
metres from the spray gun must be grounded.
• The spraying area must be kept clean and clear of any unnecessary items.
Index revision : C - March 2016
8
7105

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gnm 6080 lrNanogun-mv hrGnm 6080 hr

Table of Contents