Table of Contents

Advertisement

10.12. Barrel

• Step 1: Remove the trigger
• Step 2: Unscrew the four screws fastening the barrel on the handle.
• Step 3: Unscrew manually or with a small flat pliers the three connection wires of the high voltage
unit, pull carefully the contacts towards the back.
• Step 4: Replace the o-rings of the air ducts
and the air valve (Step 3: not obligatory):
Remove and replace the three o-rings.
• Step 5: Replace
(Step 3: obligatory): Remove and replace the o-
ring.
Replace this o-ring every year.
• Step 6: Replace the o-ring back of paint nee-
dle: Remove and replace the o-ring.
For reassembling follow the steps in reverse order.
Index revision : C - March 2016
see § 10.8 page
the o-ring
barrel/handle
36, and the paint needle.
Step 4
Step 6
40
Step 5
7105