11. For each relay: Connect a #18 AWG black wire between the relay, Pin
85 and Accessory Cable P3-1 (labeled "OUT2" on the schematic
diagrams in the service manual). Use a 1/4" tab receptacle on the relay
side and mating Molex connector and pins on the accessory cable side.
Connect the mating Molex connector to the Accessory Cable P3 when
finished (Refer to Figure 24).
12. For each relay: Connect a #18 AWG red wire to the relay, Pin 86. Cut to
length, and connect to the 1A fuse holder (supplied). Use crimp on
connectors supplied. Connect the other side of the 1 amp fuse holder to
A+ battery source or vehicle A+ fuse block. Use #18 AWG red wire and
ring lug supplied, if needed (see Figure 24).
13. Check dual control operation, using operator's manual as a test guide. In
ProGrammer, make sure the "DUAL CONTROL SPEAKER" is
programmed ACTIVE LOW.
IP
Figure 24 – M7100
44
Dual Control Unit Front Mount/Remote Mount
Installation Configuration