Certain problems might be encountered when accessory
equipment is connected to the ignition or accessory lines
of the vehicle, where these lines can have large filter
capacitors and a leakage path present. If the radio does
not turn off within a reasonable amount of time after the
ignition is turned off, first try a different accessory or
ignition sense pick-up point in the vehicle. Many vehicles
have more than one circuit that is switched by the ignition
switch, and one might be available that does not have
large filter capacitors or a leakage path present.
CAUTION
If a different pick-up point cannot be found, add a 470-
ohm, 1-watt resistor from the ignition sense pick-up point
to ground. This will discharge the capacitor(s) or reduce
the leakage voltage to a low value. Current drain through
this resistor will be minimal (less than 0.03A) when the
ignition is switched on.
Control Cable (Remote Mount Only)
The Control Cable is used to connect the Control Unit (through the RIA) to
the Radio Transceiver in remote applications. Plug P2, at one end, connects
to the Remote Control Cable Connector (RCCC) mounted on the back of the
RIA. The Ignition Sense wire is also part of P2. The connection, P5, is
available for field programming, keyloading, or mobile data applications. The
other end of the Control Cable (P1) connects to the ORCC mounted on the
back of the radio. See Figure 11.