Brakelight Switch (Handlebar Control); Coolant Temperature And Cooling Fan Switches - Arctic Cat DVX 250 2007 Service Manual

Table of Contents

Advertisement

RESISTANCE (Switch Connector)
! CAUTION
Always disconnect the battery when performing
resistance tests to avoid damaging the multimeter.
1. Set the meter selector to the OHMS position.
2. Connect the red tester lead to the brown/blue
wire; then connect the black tester lead to the
green/yellow wire.
3. When the brake pedal is depressed, the meter
must show less than 1 ohm.
NOTE: If the meter shows more than 1 ohm of
resistance, replace the switch.
Brakelight Switch
(Handlebar Control)
The switch has spade-type connectors which engage
the harness connectors at the switch.
NOTE: The ignition switch must be in the ON
position.
VOLTAGE
(Wiring Harness Connector)
1. Set the meter selector to the DC Voltage posi-
tion.
2. Connect the red tester lead to the brown/blue
wire; then connect the black tester lead to
ground.
3. The meter must show battery voltage.
NOTE: If the meter shows no battery voltage,
troubleshoot the battery, fuse, switch, or the main
wiring harness.
NOTE: If the meter shows battery voltage, the
main wiring harness is good; proceed to test the
switch/component, the connector, and the switch
wiring harness for resistance.
Back
Back to TOC
RESISTANCE (Switch)
! CAUTION
Always disconnect the battery when performing
resistance tests to avoid damaging the multimeter.
NOTE: The brake lever must be compressed for
this test. Also, the ignition switch must be in the
OFF position.
1. Set the meter selector to the OHMS position.
2. Connect the red tester lead to one spade termi-
nal; then connect the black tester lead to the
other spade terminal.
3. When the lever is compressed, the meter must
show less than 1 ohm.
NOTE: If the meter shows more than 1 ohm of
resistance, replace the switch.
Coolant Temperature
and Cooling Fan
Switches
1. Connect the meter leads (selector in the OHMS
position) to the switch contacts.
2. Suspend the switch and a thermometer in a con-
tainer of water; then heat the water.
NOTE: Neither the switch nor the thermometer
should be allowed to touch the bottom of the con-
tainer or inaccurate readings will occur. Use wire
holders to suspend switch and thermometer.
3. On the cooling fan switch when the temperature
reaches 86-90° C (187-194° F), the meter should
read a closed circuit.