●I/O Signals
Signal
OUTPUT 
Control output 
ENAB 
Enabled output 
S̲TEACH 
Stationary object teaching input 
M̲TEACH 
Moving object teaching input 
TRIG 
Measurement trigger input 
CONT 
Continuous measurement input 
BANK1 
Bank switching input (F10-C30/C35/C50/C55) 
BANK2 
 
BANK3 
 
・ All input signals are enabled in RUN mode only. 
 
●Switching Banks (F10-C30/C35/C50/C55)
You can switch banks by connecting BANK1 to BANK3 
as shown below.
Bank No
BANK1
Bank 0 
OFF 
Bank 1 
ON 
Bank 2 
OFF 
Bank 3 
ON 
Bank 4 
OFF 
Bank 5 
ON 
Bank 6 
OFF 
Bank 7 
ON
 
Function
BANK2
BANK3
OFF 
OFF 
OFF 
OFF 
ON 
OFF 
ON 
OFF 
OFF 
ON 
OFF 
ON 
ON 
ON 
ON
ON
15
4. Connection of Serial Communication
You can input the measurement trigger and output the measurement 
results via an RS-232C port. You can also back up the settings in an 
IBM PC/AT or compatible. Refer to the Operation Manual for the Unit 
for details on communications commands.
●1:1 Connection
System cnfiguration
F10-VR2 RS-232C Cable
F10-C50/C55
IBM PC/AT or 
compatible
16