●I/O Signals
Signal
OUTPUT
Control output
ENAB
Enabled output
S̲TEACH
Stationary object teaching input
M̲TEACH
Moving object teaching input
TRIG
Measurement trigger input
CONT
Continuous measurement input
BANK1
Bank switching input (F10-C30/C35/C50/C55)
BANK2
BANK3
・ All input signals are enabled in RUN mode only.
●Switching Banks (F10-C30/C35/C50/C55)
You can switch banks by connecting BANK1 to BANK3
as shown below.
Bank No
BANK1
Bank 0
OFF
Bank 1
ON
Bank 2
OFF
Bank 3
ON
Bank 4
OFF
Bank 5
ON
Bank 6
OFF
Bank 7
ON
Function
BANK2
BANK3
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
15
4. Connection of Serial Communication
You can input the measurement trigger and output the measurement
results via an RS-232C port. You can also back up the settings in an
IBM PC/AT or compatible. Refer to the Operation Manual for the Unit
for details on communications commands.
●1:1 Connection
System cnfiguration
F10-VR2 RS-232C Cable
F10-C50/C55
IBM PC/AT or
compatible
16