Read Operation in AUTO Mode

5-1

Read Operation in AUTO Mode

Data Carrier position
Data Carrier accessed
Address input
INHIBIT input
HS output
R/W input
NORMAL output
ERROR output
Data output
Data input
Data LED indicators
62
In AUTO mode, the Data Carrier (DC) can always be accessed when the
INHIBIT input is ON while the V600-HAM42-DRT power is ON. Therefore the
Data Carrier is automatically accessed when the Data Carrier enters the trans-
mission area, with no need for a simultaneous trigger (TRG) input.
Read data will be output with the data output signal while the Data Carrier is with-
in range.
If the Data Carrier is stopped within the transmission area after reading is ac-
cessed, it will not be accessed again. After the Data Carrier goes out of the trans-
mission area, or after operation is stopped by the INHIBIT input turning OFF, the
Data Carrier will revert to wait status.
Inside the area
(DC de-
Read executed (1)
tected)
Address designation input
"0"
t
auto
All 0
Data (1)
Don't Care
Previous data
None
Data (1) display
output
lit
The output time t
is the time that the Data Carrier is in the transmission area.
auto
If this time (t
) is shorter than the output time set by pin 1 of DIP switch 2 (out-
auto
put mode), the output will continue during the output time. (When the DIP switch
pin is OFF, the output time is 100 ms; when ON, the output time is 500 ms.)
Outside the area
Inside the area
(DC de-
(DC de-
Read executed (2)
tected) Read executed (3)
tected)
All 0
Data (2)
None
Data (2) display
lit
Section
5-1
(DC de-
tected)
All 0
Data (3)
None
Data (3) display
lit