Fax Maintenance
RX Settings
TX Settings
Overseas Comm Mode
Settings
Dial Pulse Setting
Determines the period when tones from the line are
monitored.
Tone Sound
Monitoring
[No Monitoring/ Up To Phase B (Default)/ All TX
Phases]
Pressing the Stop/Clear key can stop the current
receiving operation. Received data is lost.
Stop/Clear Key
[No Functional (Default)/ Functional]
Sets the off-hook detection threshold.
Off-Hook Level
[10V (Default)/ 15V/ 20V/ 25V]
Sets the Off-Hook detection period.
Off-Hook
Detection
200 msec (Default)/ 800 msec
Sets the redial interval when Tx fails.
Redial Interval
[5 Min (Default)/ 6 Min]
Sets the number of redials when Tx fails.
Redialings
[2 times/ 3 Times (Default)/ 4 Times/ 5 Times]
This sets the machine to ignore a DIS signal sent
Overseas Comm
from the called station once in a sending operation.
Mode
[Off (Default)/ Ignore DIS Once]
If this setting is set to "On", the machine detects the
CNG signal after the line is connected. If it is set to
Minimum Time
"Off", the machine detects the CNG signal as long
Length
as the line is connected.
[100 Ms/ 200 Ms/ 300 Ms/ 400 Ms (Default)]
This sets the number of pulses that are generated
during dialing.
• N: Dialing '0' generates 10 pulses --- Dialing
Dial Pulse Type
• N+1: Dialing '0' generates 1 pulses --- Dialing
• 10-N: Dialing '0' generates 10 pulses ---
'9' generates 9 pulses. (Default)
'9' generates 10 pulses.
Dialing '9' generates 1 pulse.
Service Program Mode