5. System Maintenance Reference
Fax Maintenance
Protocol Definition
Protocol Definition Timer
RX Settings
116
This sets the number of training retries to be
repeated before automatic fallback.
Training Retries
[1 Time/ 2 Times (Default)/ 3 Times/ 4 Times]
Sets the compression method for Tx/Rx.
Encoding
[MMR+MR+MH (Default)/ MR+MH/ MH]
Timeout for response from the called station in
automatic sending mode
T0 Timer
[35 Sec/ 45 Sec/ 55 Sec / 60 Sec (Default)/ 90
Sec/ 140 Sec]
Set the time length for the T1 timer.
T1 Timer
[40 Sec (Default)/ 50 Sec]
Set the time length for the T4 timer.
T4 Timer
[3 Sec (Default/ 4.5 Sec]
Silence (No tone) detection time (Rx mode : FAX/
TAD Only)
Silence Detection
After the line is connected via the external
Time
telephone, the machine can detect silence (no tone)
for the time length specified by this setting.
[30 sec (Default)]
CNG tone detection time ( RX mode : FAX / TEL,
FAX / TAD Only)
CNG Tone
After the line is connected via the external
Detection
telephone, the machine can detect a CNG signal
for the time length specified by this setting.
[5 Sec (Default)/ 10 Sec]
Number of CNG cycles to be detected
CNG Cycles
This setting is only effective for FAX/TAD mode.
[1.5 Cycle (Default)/ 2.0 Cycle]