Engine Maintenance
00* – 7F
Brand ID
Displays the current brand ID number.
Do not change this setting (Designed for Factory Use).
Fuser SC Reset
This button is for resetting an SC related with the fusing errors.
Reset Transfer
Clears the EM counter of the transfer roller.
Unit
Reset Paper
Clears the EM counter of the paper feed roller.
Feed Rol Life
Reset Fusing
Clears the EM counter of the fusing unit.
Unit
Motor Rotation
Displays the main motor rotation time.
Time
Kind ID
Toner End History
Prt
Cartridge
Info
Refill Flag Status
Unit Print Counter
OPC Rotation Time
Pre-OPC Rotation Time
OPC Life Info
OPC Alert Status
OPC Pre-Alert Status
Displays the toner cartridge (AIO) information (Kind
ID).
Displays the toner cartridge (AIO) information (Toner
End History).
Displays the toner cartridge (AIO) information (Refill
flag status).
Displays the toner cartridge (AIO) information (Unit
Print Counter).
Displays the OPC life information (OPC rotation time).
Displays the OPC life information (Pre-OPC rotation
time)
Displays the OPC life information (Alert status)
Displays the OPC life information (Pre-Alert status)