Ricoh RN-MF2 Field Service Manual page 117

Table of Contents

Advertisement

Scan Maintenance
ADF Main Reg.
ADF Sub Reg.
Registration Adjust
Flatbed Main Reg.
Flatbed Sub Reg.
ADF Main Reg.
ADF Sub Reg.
Size Adjust
Flatbed Main Reg.
Flatbed Sub Reg.
Fax Maintenance
Modem Settings
Adjusts the ADF Scan main-scan registration.
[-2.0 to 2.0 / 0 (Default)/ 0.1 %/step]
Adjusts the ADF Scan sub-scan registration.
[-2.0 to 2.0 / 0 (Default)/ 0.1 %/step]
Adjusts the Flatbed Scan main-scan registration.
[-2.0 to 2.0 / 0 (Default)/ 0.1 %/step]
Adjusts the Flatbed Scan sub-scan registration.
[-2.0 to 2.0 / 0 (Default)/ 0.1 %/step]
Adjusts the ADF Scan main-scan magnification.
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Adjusts the ADF Scan sub-scan magnification.
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Adjusts the Flatbed Scan main-scan magnification.
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Adjusts the Flatbed Scan sub-scan magnification.
[-0.9 to 0.9 / 0 (Default)/ 0.1 %/step]
Sets the reception level.
RX Level
[-43 dBm (Default)/ -33 dBm/ -26 dBm
/ -16 dBm]
Sets the transmission level.
TX Level
[-1 dBm to -15 dBm/ -15dBm (Default)/ 1 dBm/
step]
These selectors are used to improve the pass-band
characteristics of analogue signals on the
Cable Equalizer
telephone line.
[0Km (Default)/ 1.8Km/ 3.6Km/ 7.2Km]
Service Program Mode