5. System Maintenance Reference
Engine Maintenance
Waste toner
disposal
Test Pattern
Curl Control
Mode
Adjust Charge
Bias
1200dpi LD
Power
Scan Maintenance
Mono Compression
114
Independent-Supply
Toner
Prints the test pattern.
Corrects the face curl of paper.
0: OFF (28ppm)
1: Sets the engine speed at 14ppm after printing 1 minute.
2: Sets the engine speed at 14ppm.
3 to 255: not available
[0 to 255 / 0 / 1 /step]
Charge bias correction for dirty background
0: OFF (Default)
1: ON
2 to 255: not available
[0 to 255 / 0 / 1 /step]
Adjusts print density (density levels by increasing the number)
[31 to 155 / 112 (Default) / 1 /step]
Sets the monochrome compression type for scanning.
MH (Default)/ MR/ MMR
Sets the machine operation at "waste toner full" of the
refilled AIO.
[On or Off (Default)]
• With main motor rotation count feature, machine
can be set to stop printing after print total exceeds
a certain set value. If print count exceeds this
value, then "Replace Print Cartridge" remains in
display. Then a new AIO cartridge must be
installed. This feature is a safety measure to
prevent the used toner tank from becoming full
(there is no toner overflow detection mechanism).