Mode No.
2
(Class 1, 2, and 3)
109
5
Display 1200
6
Display 600
112
[Polygon OFF 1] Polygon Mirror Motor OFF Timing
1
Warming-up
2
Job End
113
[Polygon OFF 2] Polygon Mirror Motor OFF
1
Polygon OFF 2
201
[Dev. Bias] Development Bias ([Color], Process Speed)
1
[K] 62.5
2
[K] 125
3
[K] 185
4
[Y] 62.5
5
[Y] 125
6
[M] 62.5
7
[M] 125
8
[C] 62.5
9
[C] 125
[Forced Toner] Forced Toner Supply ([Color])
207
1
[K]
2
[Y]
3
[M]
4
[C]
208
[Toner Mode] Toner Supply Method ([Color])
1
[K]
2
[Y]
3
[M]
4
[C]
5
Fixed Rate [K]
6
Fixed Rate [Y]
7
Fixed Rate [M]
8
Fixed Rate [C]
PRINTER ENGINE SERVICE MODE
Function / [ Setting ]
[ 0 to 255 / - / 1 pulse/step ]
[ 0 to 255 / - / 1 pulse/step ]
*BCU The polygon mirror motor turns off if the machine
receives no print start command for the time
specified in this SP mode after receiving the print
preparation command.
[ 0 to 60 / 10 / 1 second/step ]
0: Not turned off except for Energy Saver mode
*BCU The polygon mirror motor turns off if the machine
receives no print job for the time specified in this
SP mode after the previous job was completed.
[ 0 to 60 / 10 / 1 second/step ]
0: Not turned off except for Energy Saver mode
The polygon mirror motor does not turn on until
the printer enters the ready condition even after
receiving the print start command.
[ 0 or 1 / 0 / 1 /step ]
0: Enable, 1: Disable
NOTE: When a user complains about high
frequency noise, enabling this mode can
minimize the noise.
*BCU
Adjusts the development bias.
Development bias is automatically adjusted during
*BCU
process control; therefore, adjusting these settings
*BCU
has no effect while Process Control (SP3-125
*BCU
Default: ON) is activated.
*BCU
After deactivating Process Control with SP3-125,
*BCU
the values in these SP modes are used for
*BCU
printing.
*BCU
[ 200 to 800 / 500 / 10 V/step ] DFU
*BCU
Forces toner to be supplied to the development
unit.
[ 0 or 1 / 0 / 1 /step ]
0: Not execute
1: Execute
The toner supply clutch turns on for 0.7 s and off
for 1.3 s.
*BCU
Selects the toner supply method.
[ 0 to 2 / 1 / 1/step ] Alphanumeric
*BCU
0: Fixed supply (with the supply rates stored with
*BCU
SP2-208-5 to 8)
*BCU
1: Fuzzy control supply
2: Proportional control supply (using the Vref
values stored with SP2-224-5 to 8)
*BCU
Sets the toner supply rate used when the toner
supply method (SP2-208-1 to 4) is set to '0' (fixed
*BCU
supply mode).
*BCU
[ 0 to 100 / 5 / 1%/step ]
*BCU