Ricoh J-P2 Service Manual page 151

Table of Contents

Advertisement

17 January, 2003
SC No.
Item
SC 680
BCU/ MUSIC
After the engine CPU sends a
communication
message, the Music CPU does
error
not respond within five
seconds three consecutive
times.
• During data transfer, a
SC 685
SBU-IPU
communication
(CF)
checksum error occurs.
error
• During any operation except
initialization, the SBU sends
a hardware-reset
acknowledgement to the
IPU.
• After the machine is
SC 686
BCU-IPU
communication
(CF)
powered on or recovering
error
from the power save mode,
timeout occurs during BCU
communication.
• The break signal is received
after the communication is
normally established with
the BCU.
• Timeout occurs while the
communication with the
BCU is retried after a
communication error.
SC 687
Memory
The BCU does not receive a
address
memory address command
command error
from the controller 60 seconds
after paper is in the position for
registration.
Definition
Possible Cause
• Toner cartridge
memory chip loose
connection
• Memory chip problem
• Memory chip cable
wiring problem
• Scanner unit cable
connector loose
• SBU board defective
• IPU board defective
• External noise
• Board connector
between BCU and
controller loose
• Board connector
between controller
and bridge board
loose
• Board connector
between bridge board
and IPU loose
• BCU board defective
• IPU board defective
• Controller board
defective
• Bridge board
defective
• Loose connection
• Defective controller
• Defective BCU
Related
SCs
1. Turn the main switch off and on.
2. Check if the toner cartridge is
installed correctly.
3. Replace the toner cartridge.
4. Check if the harnesses are not
damaged.
5. Replace the BCU.
1. Turn the main switch off and on.
2. Shut out the external noise.
3. Check the cable connection of the
scanner unit.
4. Replace the SBU board.
5. Replace the IPU board.
1. Turn the main switch off and on.
2. Check the cable connection between
the board connector and BCU.
3. Check the cable connection between
controller and bridge board.
4. Check the cable connection between
bridge board and IPU.
5. Replace the BCU board.
6. Replace the IPU board.
7. Replace the controller board.
8. Replace the bridge board.
1. Turn the main switch off and on.
2. Check if the controller is firmly
connected to the BCU.
3. Replace the controller.
4. Replace the BCU.
4-29
Troubleshooting Procedure
SC TABLE
Type
B