CALIBRATING THE TOUCH PANEL

To initialize the SP settings

Follow this procedure to initialize the SP settings and restore them to their factory
default settings.
1. Enter the SP Mode. (☛ 5.4.2)
2. Print an SMC list (see the procedure above).
3. To initialize the SP settings, enter 5801, press ', and then press Start.
NOTE: The total counter is not cleared when RAM is cleared.
4. After initializing the SP settings, use SP5811 to re-enter the serial number of
the machine.
5.5 CALIBRATING THE TOUCH PANEL
Follow this procedure to calibrate the touch panel.
1. On the operation panel, press #++,.
2. Press and release * 5 times to open the menu.
3. Without touching the touch panel, press '. After a few moments, two circles
will appear, one in the upper left corner and one in the lower right corner.
4. With a blunt instrument, press the circle in the upper left corner.
CAUTION: Never press the touch panel with a sharp object.
5. Touch the center of the circle in the lower right corner.
6. Touch any location on the touch panel, and make sure that the a circle appears
at the point you touched.
7. Repeat 6 several times to confirm that the touch panel is correctly calibrated.
8. To leave the touch panel calibration mode, press OK, press q:EXIT, then press
EXECUTE.
9. Wait for the panel to go off, then turn the machine off and on.

5.6 SOFTWARE RESET

To reset the software, hold down
reset is the same as turning the machine off on and with the main power switch.
You cannot use this procedure to reset the software when the operation panel has
stalled or if a fusing-related SC code has appeared.
and ' together for 10 seconds. This software