Ricoh Aficio 480W Dolphin-C2 Service Manual page 33

Table of Contents

Advertisement

28 April 2005
[B]
14. Open the toner hopper cover.
15. Remove the left exit tray [A].
16. Remove the strip of tape [B] from the corona wire cleaner, then reinstall the exit
tray (! x 2).
!
CAUTION
The tape is looped around the corona wire drive screw. To avoid
damaging the drive screw, gently peel the tape from the mylar or cut it
with scissors.
17. Close the toner hopper cover and open the upper unit.
18. Place a level [C] in the middle of the guide plate as shown in the illustration.
Make the machine level by turning the bolts [D] on the machine's four feet.
NOTE: The gap [E] must be less than 2 mm for the bolt to clear the roll feeder
(option) when the feeder is opened and closed.
[A]
B010I203.WMF
[C]
1-11
COPIER (B188)
[C]
[D]
[E]
B010I518.WMF