Figure 42. Adapter removal
If you are instructed to return the server component or optional device, follow all packaging instructions,
and use any packaging materials for shipping that are supplied to you.

Replacing a ServeRAID adapter

Use this information to replace an IBM ServeRAID adapter.
For configuration information, see the ServeRAID documentation at http://www.lenovo.com/support.
Important: To ensure that any of your ServeRAID adapters function properly on UEFI-based servers, make
sure that the adapter firmware and supporting device drivers are updated to at least 11.x.x-XXX.
Read the safety information in "Safety" on page v and "Installation guidelines" on page 33.
If you are replacing a server component in the server, you need to turn off the server and peripheral devices,
and disconnect the power cords and all external cables.
To replace an IBM ServeRAID adapter, complete the following steps.
Note: If possible, backup or record your RAID configuration information before replacing the adapter. See
the documentation for your RAID adapter for information and instructions. Documentation for ServeRAID
adapters can be downloaded from http://www.lenovo.com/support.
Step 1.
Remove the cover (see "Removing the cover" on page 131).
Step 2.
Remove the PCI riser-card assembly (see "Removing the PCI riser-card assembly" on page 136).
Step 3.
Remove the expansion-slot cover on the slot that you intend to use and save for future use.
Attention: PCI expansion-slot covers must be installed on all vacant slots. This maintains the
electronic emissions standards of the server and ensures proper ventilation of server components.
Expansion-slot cover
Expansion slot 2
Expansion slot 1
Expansion-slot cover
Adapter
.
Chapter 6
Removing and replacing components
143