Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0536
User Response
No action; information only.
• 800b0108-1301ffff : Redundancy Lost for [RedundancySetElementName] has asserted. (Power
Unit)
This message is for the use case when Redundancy Lost has asserted.
May also be shown as 800b01081301ffff or 0x800b01081301ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Redundant Power Supply
SNMP Trap ID
9
CIM Information
Prefix: PLAT ID: 0802
User Response
1. Check the LEDs for both power supplies.
2. Follow the actions in Power-supply LEDs.
• 806f0007-0301ffff : [ProcessorElementName] has Failed with IERR. (CPU 1)
This message is for the use case when an implementation has detected a Processor Failed - IERR
Condition.
May also be shown as 806f00070301ffff or 0x806f00070301ffff
Severity
Error
Serviceable
Yes