Lenovo System x3250 M4 Installation And Service Manual page 425

Table of Contents

Advertisement

2. If system boots to F1 setup, flash UEFI image and reset bank to primary (if required). If system
boots without error, recovery is complete and no additional action is required.
3. If system fails to boot, or if flash attempt fails, (Trained service technician only) Replace the
system board.
I.58015 [I.58015] Memory spare copy initiated.
Explanation: Spare Copy Started
Severity
Info
User Response
Complete the following steps:
1. No user required for this event. This is for informational purposes only.
I.580A4 [I.580A4] Memory population change detected.
Explanation: DIMM Population Change Detected
Severity
Info
User Response
Complete the following steps:
1. Check system event log for uncorrected DIMM failures and replace those DIMMs.
• I.580A5 [I.580A5] Mirror Fail-over complete. DIMM number % has failed over to to the mirrored
copy.
Explanation: DIMM Mirror Fail-over Detected
Severity
Info
User Response
Complete the following steps:
1. Check the system-event log for uncorrected DIMM failures and replace those DIMMs.
• I.580A6 [I.580A6] Memory spare copy has completed successfully.
Explanation: Spare Copy Complete
Severity
Info
User Response
Complete the following steps:
1. Check system log for related DIMM failures and replace those DIMMs.
Appendix B. UEFI (POST) error codes
411

Advertisement

Table of Contents
loading