Lenovo System x3250 M4 Installation And Service Manual page 423

Table of Contents

Advertisement

2. Check IBM support site for an applicable service bulletin or firmware update that applies to
this Processor error.
3. (Trained Service technician only) Replace the system board.
I.1800F [I.1800F] A processor family mismatch has been detected for one or more processor
packages.
Explanation: Processors have mismatched Family
Severity
Error
User Response
Complete the following steps:
1. Verify that matching Processors are installed in the correct Processor sockets according to the
service information for this product
2. Check IBM support site for an applicable service bulletin or firmware update that applies to
this Processor error.
3. (Trained Service technician only) Replace the system board.
• I.18010 [I.18010] A processor stepping mismatch has been detected for one or more processor
packages.
Explanation: Processors of the same model have mismatched Stepping ID
Severity
Error
User Response
Complete the following steps:
1. Verify that matching Processors are installed in the correct Processor sockets according to the
service information for this product.
2. Check IBM support site for an applicable service bulletin or firmware update that applies to
this Processor error.
3. (Trained Service technician only) Replace the system board.
• I.2018002 [I.2018002] The device found at Bus % Device % Function % could not be configured
due to resource constraints. The Vendor ID for the device is % and the Device ID is %.
Explanation: OUT_OF_RESOURCES (PCI Option ROM)
Severity
Info
User Response
Complete the following steps:
1. If this PCIe device and/or any attached cables were recently installed, moved, serviced or
upgraded, reseat adapter and any attached cables.
Appendix B. UEFI (POST) error codes
409