• S.3060007 [S.3060007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Reflash UEFI image.
3. (Trained service technician only) Replace the system board.
• S.3070007 [S.3070007] A firmware fault has been detected in the UEFI image.
Explanation: Internal UEFI Firmware Fault Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Reflash UEFI image.
3. (Trained service technician only) Replace the system board.
S.3818004 [S.3818004] The CRTM flash driver could not successfully flash the staging area. A
failure occurred.
Explanation: CRTM Update Failed
Severity
Error
User Response
Complete the following steps:
1. Continue booting sytem. If system does not reset, manually reset the system.
2. If the error is not reported on the subsequent boot, no additional recovery action is required.
3. If the error persists, continue booting system and reflash UEFI image.
4. (Trained service technician only) Replace the system board.
• S.3818007 [S.3818007] The firmware image capsules for both flash banks could not be verified.
Explanation: CRTM image capsule could not be verified
Severity
Error
Appendix B. UEFI (POST) error codes
415