Example of Communications Program

4-5

Example of Communications Program

Host Link Serial System
Example of System Configuration
Example of BASIC Program
48
RS-232C
In this example, data is written from Data Carrier 1 as HEX code by the write
command. Input the write address in four characters in the range of 0006 to
1FFF, and write data as 2-digit HEX characters. The total character length of the
write data must be 256 or less. Set the communication format of the ID Controller
by using the DIP switches in accordance with the communication system of the
host computer to be used.
10
CLS
20
OPEN "COM1:9600,E,8,1,CS0,DS0,CD0,PE" AS#1
30
WIDTH #1.255
40
PRINT "write command is executed"
50
INPUT "write address (HEX data: 0006–01FF)"=WA$
60
INPUT "write data (HEX data: 2–digit units)":WD$
70
TX$="WTH1"+WA$+WD$+"∗"+CHR$(&HD)
80
PRINT TX$
90
PRINT #1, TX$;
100
INPUT #1, RX$
110
PRINT "RS data=":RX$
120
GOTO 40
Note The above program is for IBM-PC. The program differs depending on the host
computer to be used.
Section
4-5