Names and Functions of Parts
Power Supply and External Output Terminals
External Output Terminals
R/W Head Connector
RS-232C Interface
Connector
Name
24VDC/0V
Supplies 24 VDC
Protective conductor terminal. Connect a ground line grounded at
GR
less than 100 Ω.
RESET
External reset input for emergency stop.
TRIG
Trigger input informing the Controller of the processing start time
of the DC. The conditions under which this input signal is to be
issued can be set by the DIP switch.
IN1
User input 1 that can be manipulated by a command.
IN2
User input 2 that can be manipulated by a command.
COM
Common input terminal.
Name
RUN
Turns ON when the ID Controller operates normally and can
communicate with the host controller. This signal is turned OFF in
the test mode.
CMPL
Turns ON when communications with the DC have been
completed, and turns OFF when transmission of a response has
started.
OUT1
User output 1 that can be manipulated by a command.
OUT2
User output 2 that can be manipulated by a command.
Connects the R/W Head (R/W Antenna).
Connector for communications with the host computer. Conforming to
RS-232C, this connector can be connected to a general-purpose factory com-
puter or personal computer.
Section
Function
Function