Omron V600-CD1D-V2 Operation Manual page 26

Serial interface id controller
Hide thumbs Also See for V600-CD1D-V2:
Table of Contents

Advertisement

RS-232C Interface Connection
Assembly of Connector
1, 2, 3...
1. Process the ends of the cables.
40
5
Core
Shield mesh
10±1
Shield tape
12
• Run the cable bushing through the cable in advance.
• Loosen the shield mesh and return it on the cable bushing. At this time,
keep the returning length to about 10 mm.
• Wind the shield tape onto the shield mesh.
2. Solder the cores of the cables to the pins.
Plug Crossover line
Aluminum tape
Pin no.
Abbr.
1*
GR
Frame ground
9
SG
Signal ground
2
SD
Send data
3
RD
Receive data
4**
RS
Request to send
5**
CS
Capable to send
*GR is grounded to the connector hood and is therefore connected to the GR of
the ID Controller through the connector hood. It is therefore unnecessary to con-
nect GR to pin 1.
**Short-circuit pins 4 (RS) and 5 (CS) with a crossover line.
3. Set the plug to the housing A2 of the hood and clamp the aluminum tape.
Lock screw (2-M2.6)
Housing A2
Cable clamp
4. Set the two connector tightening screws and attach housing B2 to A2 to
complete the connector.
35
Cable bushing
Cable bushing
Signal name
Housing B2
Section
3-6
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V620-cd1dV600-cd1d-v3