Omron V600-CD1D-V2 Operation Manual page 30

Serial interface id controller
Hide thumbs Also See for V600-CD1D-V2:
Table of Contents

Advertisement

Movement of Data Carrier and Command Status
Read/Write Function
1, 2, 3...
Read/Write Command Processing: The read/write function is used for commu-
nication when the Data Carrier is motionless. Therefore, it must be confirmed
that the Data Carrier is at a specified position, i.e., in the communication area of
the R/W Head. If the Data Carrier is missing, the ID Controller returns a response
to that effect.
(Host computer)
Read/Write
command
Command end
1. The host computer confirms that the Data Carrier is at a specified position
and transmits a command to the ID Controller.
2. The ID Controller performs write or read processing in accordance with the
command.
3. After the processing is complete, the ID Controller returns a response to the
host computer to indicate that the processing has ended. The host comput-
er, on receiving the response, moves the workpiece (with a Data Carrier) on
the conveyor line.
(ID Controller)
(Data Carrier)
Not approaching
Data Carrier
Stops
Read/Write
Data Carrier
processing
Stops
Response
Moves
Section
4-1
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

V620-cd1dV600-cd1d-v3

Table of Contents