DIP Switch Setting
Dip Switch Settings
DIP Switch 1
SW1
Display mode
0
Error Display Mode
1
I/O Display Mode
SW2
SW3
Transmission
speed (bps)
0
0
2,400
0
1
4,800
1
0
9,600
1
1
19,200
SW4
SW5
SW6
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
SW7
Local communications mode setting
1
Speed priority mode
0
Distance priority mode
The setting of SW7 is only valid if the EEPROM-type (batteryless-type) Data
Carrier (DC) is accessed. The setting of SW7 does not work with the SRAM-type
(battery-type) DC. Refer to the R/W Head Manual and Data Carrier Manual for
details. SW7 must be set to OFF when the V620 is used.
SW8 is not used. (Keep it switched OFF.)
DIP Switch 2
SW1
SW2
Synchronous
condition
0
0
OFF (LL level)
0
1
ON (HL level)
1
0
Trailing edge
1
1
Leading edge
SW3 through SW7 are not used. (Keep them switched OFF.)
Before setting the switches, be sure to turn OFF the Power to the ID Controller.
The switch settings are read when Power is switched ON. To change the switch
settings, turn OFF the Power once, change the setting, and then turn ON the
Power again.
Data
STOP
Parity
length
bits
type
(bit)
(bit)
7
2
Even
7
2
Odd
7
1
Even
7
1
Odd
8
2
None
8
1
None
8
1
Even
8
1
Odd
Section
3-1
13

Hide quick links: