Specifications and Ratings
I/O Specifications
External I/O Specifications
Input Specifications (RESET, TRIG, IN1, IN2)
Output Specifications (RUN, CMPL, OUT1, OUT2)
Note 1. When the RESET input is ON, the CPU stops and the STOP indicator light.
2. If the terminals are short-circuited without load, the internal transistor may be damaged.
72
Input voltage
Input impedance
Input current
ON voltage
OFF voltage
Input response time
Max. switching
capacity
Leakage current
Residual voltage
+10%
24 VDC
/
(including ripple)
–15%
2.2 kΩ
10 mA at 24 VDC (typical)
19 V min.
5 V max.
70 ms max.
+10%
24 VDC
/
(including ripple), 100 mA
–15%
100 µA max
2.0 V max.