Omron V600-CD1D-V2 Operation Manual page 77

Serial interface id controller
Hide thumbs Also See for V600-CD1D-V2:
Table of Contents

Advertisement

Specifications and Ratings
Communications Specifications
The communications specifications conform to RS-232C, and a general-purpose factory computer or personal
computer can be connected to the ID Controller. The communications protocol conform to SYSWAY (SYSMAC
host computer system).
Host Computer Communications Specifications
Standard
Transmission path
connection
Communications method
Synchronization method
Transmission rate
Transmitted codes
Communications control
procedure
Error detection
Line length
Connector
Recommended cable
Note *Set by the internal DIP switch.
74
RS-232C
Point-to-point
Two-line, half-duplex
Start-stop synchronization (stop bit = 1 or 2)*
2,400/4,800/9,600/19,200 bps*
ASCII (7 bits) or JIS*
Point-to-point procedure
Vertical parity (even/odd/none)*
15 m max.
XM2A-0901 (plug):
1 set is supplied with ID Controller
XM2S-0911 (hood):
As an accessory
5PX28AWG, 7 dia.
Appendix C