Omron V600-CD1D-V2 Operation Manual page 24

Serial interface id controller
Hide thumbs Also See for V600-CD1D-V2:
Table of Contents

Advertisement

Wiring
Recommended Power Supply (Small, DIN Rail Type) <OMRON>
Input and Output lines
RESET Signal Input
ERROR Signal Output
flows into the ID Controller upon Power application. Take appropriate measures
against the inrush current.
Use a power cable 2 mm
of twisted pair cables is recommended.
To improve noise immunity, ground at less than 100 Ω. For a ground cable, use a
2
cable of 2 mm
diameter minimum (green cable), and keep the cable length to
within 20 m.
Model
S82K-0124
24 VDC, 0.6 A
S82K-2124
24 VDC, 0.6 A
Note Although the rated power dissipation of the ID Controller is 24 VDC, 0.3 A (7.2
W), take into consideration the power supply ratings taking the inrush current
into the ID Controller. Use a power supply of 24 VDC, 0.6 A minimum.
RESET input
+
24 VDC
Make sure that the input voltage of the RESET signal does not exceed the maxi-
mum voltage (26.4 V). If this is exceeded, the ID Controller may malfunction.
To improve the noise immunity, separate the wiring of the input lines from
high-tension equipment or power lines.
The maximum switching capacity of the output terminals is 24 VDC (
100 mA. If a voltage or load that exceeds the maximum switching capacity is
used, the ID Controller may malfunction. Use of an auxiliary relay (24 VDC, 100
mA max.) in the output circuit is recommended.
2
diameter minimum to prevent voltage drops. The use
Output
Input voltage
100 VAC
200 VAC
+
24 VDC
To ERROR output
Section
3-5
+10%
/
),
–15%
19