Resetting the Unit

There are four unit reset modes (numbered 1, 3, 4, and 5). These are available by pressing
the recessed
access it (see the table below for a summary of the reset modes).
CAUTION: Review the reset modes carefully. Using the wrong reset mode may result
ATTENTION : Étudier attentivement les différents modes de réinitialisation.
NOTE: The reset modes listed close all open IP and Telnet connections and all
sockets. Each mode is a separate function, not a continuation from mode 1 to
mode 5.
Mode
Activation
1
Hold down the recessed Reset
button while applying power to the
unit.
NOTE:
After a mode 1 reset is performed,
update the firmware of the unit to the
latest version. Do not operate the
DVS 304 firmware version that results
from the mode 1 reset. This mode
temporarily resets the unit to factory
default until power is recycled. If you
want to use the factory default firmware,
you must upload that version again.
3
Hold down the Reset button for
about 3 seconds until the Power
LED blinks once, then release and
press Reset momentarily (<1 second)
within 1 second*.
4
Hold down the Reset button for
about 6 seconds until the Power
LED blinks twice (once at 3 seconds,
again at 6 seconds). Then, release
and press Reset momentarily (for <1
second) within 1 second*.
5
Hold down the Reset button for
about 9 seconds until the Power
LED blinks three times (once at 3
seconds, again at 6 seconds, again
at 9 seconds). Then, release and
press Reset momentarily (for <1
second) within 1 second*.
*For modes 3, 4, and 5, nothing happens if the momentary press does not occur within 1 second
Figure 23.
button on the rear panel with a pointed stylus, pen, or similar to
Reset
in unintended loss of flash memory programming, port reassignment, or
processor reboot.
le mauvais mode de réinitialisation peut causer une perte inattendue de la
programmation de la mémoire flash, une reconfiguration des ports ou une
réinitialisation du processeur.
DVS 304 Reset Mode Summary
Result
The DVS 304 reverts to the factory
default firmware. Event scripting does not
start if the unit is powered on in this mode.
All user files and settings (such as drivers,
adjustments, and IP settings) are maintained.
NOTE:
If you do not want to update
firmware, or you performed a mode 1
reset by mistake, cycle power to the
unit to return to the firmware version
that was running prior to the mode 1
reset. Use the 0Q SIS
confirm that the factory default firmware
is no longer running (look for asterisks
following the version number).
Mode 3 turns events on or off. If the
events are currently stopped after the
momentary press, the power LED flashes
twice, indicating the starting of events.
If the events are currently running after the
momentary press, the Power LED flashes
three times indicating the stopping of events.
Mode 4:
Enables ARP capability
Sets the IP address back to factory default
(192.168.254.254)
Sets the subnet back to factory default
Sets the default gateway address to the
factory default
Sets port mapping back to factory default
Turns DHCP off
Turns events off
Mode 5 performs a complete reset to
factory defaults (except the firmware).
Does everything mode 4 does
Clears driver-port associations and port
configurations
Removes button configurations
Resets all IP options
Removes scheduling settings
Removes/clears all files from the unit
Reset Mode Comparison
Purpose and Notes
Use mode 1 to revert to the factory
default version if incompatibility issues
arise with user-loaded firmware.
NOTE:
User-defined Web pages
may not work correctly if using
an earlier firmware version.
command to
Mode 3 is useful for troubleshooting.
Mode 4 enables you to set IP address
information using ARP and the MAC
address.
Mode 5 is useful if you want to start
over with configuration and uploading,
and also to replace events.