Figure 27.

Symbol Definitions

• = Space
] = Carriage return with line feed
} = Carriage return with no line feed
| = Pipe (can be used interchangeably with the
E = Escape
W = Can be used interchangeably with the
= Superscripts indicate the error message displayed if the command is entered
14, 24, 27, 28
incorrectly or with invalid parameters (s
the previous page)
X! = Specific port number (01-99)
X@ = Command data section
NOTE:
if it is non-alphanumeric. Because data can include either command terminator, it must be
encoded as follows when used within the data section:
Space (Hex 20) must be encoded as %20 (Hex 25 32 30).
Plus sign (Hex 2B) must be encoded as %2B (Hex 25 32 42).
X# = Greenwich Mean Time (GMT) offset value (-12:00 to 14:00) in hours and minutes (hh:mm)
X% = On/Off: 0 = off/disable, 1 = on/enable
X1! = Version number (listed to 2 decimal places)
X1@ = Name is a text string of up to 24 characters drawn from the alphabet (A-Z), digits (0-9), and
the minus sign/hyphen (-). The first character must be an alpha character. The last character
must not be a minus. No blank or space characters are permitted, and no distinction is made
between upper- and lowercase.
X1# = Local date and time format
Set format (MM/DD/YY-HH:MM:SS); for example, 02/4/16-10:54:00
Read format (day, date month year (HH:MM:SS), for example, Thu, 4 Feb 2016 18:19:33
X1$ = IP address (xxx.xxx.xxx.xxx); leading zeros in each of 4 fields are optional in setting
values, and are suppressed in returned values.
X1% = Mail domain name (for example, Extron.com)
X1& = Time in tens of milliseconds to wait for characters coming into a serial port before terminating
the connection (min. = 0, max. = 32767, and default = 10 = 100 ms). The response is returned
with leading zeros. In RS-232 commands, X1& is optional.
X1* = Hardware (MAC) address (xx-xx-xx-xx-xx-xx)
X1( = Subnet mask (xxx.xxx.xxx.xxx). Leading zeros are optional in setting values in each of four
fields, and are suppressed in returned values.
ASCII to Hex Conversion Table
ASCII to Hexadecimal Character Conversion Table
.
For Web encoding only: data is directed to the specified port and must be encoded
DVS 304 Series • SIS Communication and Control
}
character)
E
character
ee
Error Response References
section on
33