220817
Metric
Material
Torch-to-Work
Thickness
Distance
mm
mm
2
3
4
6
8
1.5
10
12
16
20
English
Material
Torch-to-Work
Thickness
Distance
inches
inches
16 GA
14 GA
10 GA
3/16
1/4
0.06
3/8
1/2
5/8
3/4
7/8
Gas flow rate – slpm / scfh
151 / 320
184 / 390
Powermax45 XP
Operator Manual
Stainless Steel – 45 A – Air – Shielded
220854
220941
(220953 for
ohmic sensing)
Pierce
Initial Pierce Height
Delay Time
mm
%
seconds
0.1
0.2
0.4
3.8
250
0.6
0.8
4.6
300
1.2
Edge Start
Pierce
Initial Pierce Height
Delay Time
inches
%
seconds
0.1
0.2
0.4
0.15
250
0.5
0.6
0.8
0.18
300
1.2
Edge Start
Hot (cutflow)
Cold (postflow)
809240
Cut Charts and Marking Charts
220842
Best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
mm/min
volts
mm/min
5620
126
7830
3285
129
4725
1995
130
2960
1145
131
1695
830
134
1100
605
137
870
380
141
540
240
145
320
160
149
205
Best Quality Settings
Production Settings
Cut Speed
Voltage
Cut Speed
in/min
volts
in/min
237
125
320
230
126
320
90
130
134
63
131
93
40
131
59
26
137
29
12
142
19
10
145
13
7
148
5
151
9
220857
Kerf Width
Voltage
volts
mm
129
0.6
128
0.9
129
1.1
131
1.2
134
1.4
137
1.6
139
1.8
142
2.4
146
3.1
Kerf Width
Voltage
volts
inches
128
0.017
129
0.022
128
0.041
130
0.044
131
0.047
136
0.061
140
0.075
142
0.096
9
145
0.116
6
149
0.137
125
Need help?