Page 1
Powermax45 Control Board Replacement Kit Kit de remplacement du CI de commande du Powermax45 Field Service Bulletin Bulletin de service sur le terrain 805860 – Revision 1 – March, 2009 Révision 1 – Mars, 2009...
Disconnect electrical power before performing any maintenance. See Section 1 of the Operator Manual for more safety precautions. Introduction Purpose This field service bulletin describes the necessary steps for replacing the Powermax45 control board. Tools and materials needed #2 Phillips screwdriver 228262 Kit contents...
POWERMAX45 CONTROL BOARD REPLACEMENT KIT Replace the control board 1. Turn OFF the power, disconnect the power cord, and disconnect the gas supply. 2. Remove the 2 screws from the handle on the top of the power supply. Remove the handle and then lift the cover off the power supply.
Page 4
Voir la section 1 du Manuel de l’opérateur où l’on donne davantage de mesures de sécurité. Introduction Objet Ce bulletin de service sur le terrain décrit les étapes nécessaires pour remplacer le CI de commande du Powermax45. Outils et matériaux nécessaires Tournevis Phillips n Composition du nécessaire Nécessaire 228262...
Page 5
KIT DE REMPLACEMENT DE CI DE COMMANDE DU POWERMAX45 Remplacer le CI de commande 1. Couper l’alimentation (OFF), déconnecter le cordon d’alimentation et débrancher le gaz d’alimentation. 2. Desserrer les 2 vis de la poignée à la partie supérieure de la source de courant. Déposer la poignée puis soulever le capot pour le sortir de la source de courant.