Setup Data Assignment Using CLI

This section describes data assignment for WL Controller and WL Access Points
by using Command Line Interface (CLI).

Before Doing This Task

When you perform data assignment using CLI, the following information are
required:
IP address and subnet mask for a WL Controller
l
Default Gateway's IP address and subnet mask
l
RADIUS Server's IP address
l
Besides, PC and WL Controller must be connected directly. The following are
network settings at initial state.
IP address: 192.168.100.10
Subnet address: 255.255.255.0
Assign the appropriate network settings to PC. And then use a cross-over cable to
connect them.
The following is an example when PC is connected to SCA-WL10. WL5100 is
also connected through Ether 1 connector.
Front
PWR
ALM
ACT
LOAD
INITIAL SETUP
100M LINK 100M LINK
Ether1
Ether2
10BASE-T/100BASE-TX Cross-over Cable
Setup PC
Example of Network Settings