Connecting the external control unit to the drive module

WARNING! Handle the fiber optic cables with care. When unplugging optic
cables, always grab the connector, not the cable itself. Do not touch the ends of
the fibers with bare hands as the fiber is extremely sensitive to dirt.

Routing the control unit cables into the drive module

Route the control unit connection cables to the drive module through the slot in the middle
front cover at the front or left side or from below or above. For routing through the slot in
the middle front cover, remove the plate which covers the slot. Then, install the rubber
grommet from the accessories box item 2 in the drawing, page 90).

Connections to the drive module

Connect power supply cable of the control unit to the BPOW connector and the ground
wire of the cable to the ground terminal.
Connect the BGDR cable to the BGDR connector.
Connect the fiber optic cables to the V20 and V10 connectors.
Secure the cables at the clamps.
BPOW
BGDR
V10, V20
Installation instructions 103
BPOW grounding wire