32 Operation principle and hardware description
1a
1b
2
1
Clear plastic shroud to be attached onto the
drive module input power cabling (a). Lead-
through shroud for side cabling (b).
2
Clear plastic shrouds to be attached onto the
drive module output power cabling
3
Clear plastic shroud to be attached on top of
the drive module (lead-through for top cabling)
4
Upper back clear plastic shroud
5
Lower back clear plastic shroud
6
Front clear plastic shroud
7
Input power cable connection terminals
(option +H370)
8
Output power cable connection terminals
9
Grounding terminal for output power cable
shields
10
Metallic shroud. With option +H370, the
shroud includes a ground bar.
3
+H370
7
4
8
5
9
20
11
12
13
14
15
16
17
18
19
20
10
11
12
13
15
14
Fiber optic cables
PE (ground) terminal
Main cooling fans
Pedestal guide plate
Telescopic extraction and insertion ramp
External control unit. The control unit can also
be inside the drive module (option +P905)
Control panel
Control cable clamp plate
Cables for connecting the control unit to the
drive module
Bottom grille with mounting bracket
6
16
17
18
19

Hide quick links: