SUREFIRE ELECTRONIC IGNITION SYSTEM
S.I.T. PROFLAME 2 TROUBLESHOOTING
POTENTIAL CAUSES FOR FLAME SENSOR NOT TO PROVE
Venting Related Issues (See each manual for specific information relating to tested and approved venting
systems)
Partial Intake Liner - intake and exhaust liners must be of approved size and run continuous to termination
Unapproved Termination
Unapproved Vent Configuration
Enclosed Termination
Incorrect Vent Restrictor Setting
Crossed Liners
Silicone sealant used on venting.
If Liners have large sags, pull liners tight and keep run as straight as possible
Gas Supply Issues (See each units manuals for required pressure)
Ensure Sediment Trap (Drip Leg) is installed in supply line prior to the gas valve.
Measure static and working pressures on inlet and outlet taps
Measure Outlet Gas Pressure with unit ON(call for heat)
If inlet working pressure is to low check for blockage or incorrect gas line size
If outlet working pressure is incorrect and inlet pressure is correct check the following:
Converted Units - verify adherence to proper conversion instructions
Cold Vents/ Cold Start - unit may need to be cycled again to overcome the cold vent/cold start
Turn unit OFF, then back ON to cycle the unit again
Misplaced logs/glass or stone - check manual for correct certified media placement
SimTech Proflame II