SUREFIRE ELECTRONIC IGNITION SYSTEM
S.I.T. PROFLAME 2 TROUBLESHOOTING
Diagram 3
VOLTS DC TEST (VDC)
Verify the battery voltage at IFC terminal connection X5, positions 1 and 2. Reading should be between 5 and 7 VDC. If
the reading is 4.4 VDC or less, replace the batteries. If 5V or more, see next Step.
SimTech Proflame II
36