Quick Start Guide
Unidrive M400
Frame sizes 1 to 4
Manufacturing Automation drive
Fast set-up and diagnosis with
real-text display, plus integrated
CODESYS based PLC
Part Number: 0478-0040-05
Issue: 5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Unidrive M400 and is the answer not in the manual?

Questions and answers

Jeff Snyder
April 25, 2025

I need a description of what each button does.

1 comments:
Mr. Anderson
May 13, 2025

On the Emerson Unidrive M400, the keypad buttons have the following functions:

- Up and Down buttons pressed together: Set the parameter value being edited to 0.
- Left and Right buttons pressed together: Select the least significant digit (furthest right) on the display for editing.
- Up or Down button alone: Scroll through parameters. The list rolls over, so reaching the last parameter continues to the first.
- Left or Right button alone: Navigate within a parameter or menu (if enabled).
- Movement between menus is only possible if all menus have been enabled (Pr 00.010).

This answer is automatically generated

Summary of Contents for Emerson Unidrive M400

  • Page 1 Quick Start Guide Unidrive M400 Frame sizes 1 to 4 Manufacturing Automation drive Fast set-up and diagnosis with real-text display, plus integrated CODESYS based PLC Part Number: 0478-0040-05 Issue: 5...
  • Page 2 This guide is intended to provide basic information required in order to set-up a drive to run a motor. For more detailed installation information, please refer to the Unidrive M400 User Guide which is available to download from: www.controltechniques.com/userguides or www.emersonindustrial.com/en-EN/leroy-somer-motors- drives/downloads/Pages/manuals.aspx...
  • Page 3: Table Of Contents

    4 ................. 34 10.8 Motor overload protection ..................34 10.9 Motor overspeed protection ................... 34 10.10 Thermal memory retention ..................34 10.11 Group installation ....................35 10.12 UL listed accessories ..................... 35 Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 4 <16 A EN 61000-3-2:2006 Applicable where input current <16 A. No limits apply for professional equipment where input power >1 kW. Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 5 EC type-examination has been carried out by the following notified body: TÜV Rheinland Industrie Service GmbH Alboinstraße 56 12103 Berlin, Germany Notified Body identification number: 0035 EC type-examination certificate number: 01/205/5383.00/14 and 01/205/5387.00/14 Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 6 EMC. The assembler is responsible for ensuring that the end product or system complies with all the relevant laws in the country where it is to be used. Refer to the User Guide. Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 7: Product Information

    04400135 16.3 13.5 04400170 20.7 The nominal cable sizes shown in the table above, are provided as a guide only. Ensure NOTE that the cables used conform to the local wiring regulations. Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 8: Options

    Type Option module Color Name Further details Purple SI-PROFIBUS Medium SI-DeviceNet Grey Light Grey SI-CANopen Fieldbus See relevant option module User Guide Beige SI-Ethernet Brown Red SI-EtherCAT Automation Orange SI-I/O (I/O expansion) Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 9: Mechanical Installation

    Size 6.30 2.95 130 5.12 5.70 2.08 8.07 3.07 150 5.91 7.63 2.17 0.00 0.00 3.93 8.90 3.54 160 6.30 8.46 70.7 2.80 277 10.91 115 4.53 175 6.89 10.43 3.40 0.23 Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 10 5. Control connections 6. Braking terminal 7. Internal EMC filter screw 8. DC bus + 9. DC bus - 10. Motor connections 11. AC supply connections 12. Ground connections 13. SAFE TORQUE OFF connections Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 11: Electrical Installation

    40 °C (104 °F) Table 4-1 Braking resistor resistance and power rating (100 V) Minimum Instantaneous Continuous Model resistance* power rating power rating Ω 01100017 0.25 01100024 0.37 02100042 0.75 02100056 Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 12: Ground Leakage

    9.36 mA* AC at 110 V, 50 Hz (2 phase, line to line supply, star point ground) 16.4 mA* AC at 110 V, 50 Hz (1 phase, line to neutral supply, star point ground) 5.3 mA* AC at 230 V, 50 Hz (3 phase supply, star point ground) Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 13 Type A can only be used with single phase drives • Type B must be used with three phase drives Only type B ELCB / RCD are suitable for use with 3 phase inverter drives. WARNING Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 14: Control Terminal Configurations And Wiring

    Action will only occur if the drive is inactive, not in UU state and no User Actions are running. Otherwise, the parameter will return to its pre altered value on exit from edit mode. All parameters are saved if this parameter changes. Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 15 Analog output 2 (motor active current) + 24 V output Digital output (zero frequency) Unassigned Run forward Run reverse Analog input 1/ input 2 select Jog Forward Unassigned + 24 V output Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 16 Terminal 5 Terminal 14 Reference selected Jog Forward Analog reference 1 ( 01.036 Preset speed 2 ( 01.022 Unassigned Preset speed 3 ( 01.023 Preset speed 4 ( 01.024 + 24 V output Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 17 Analog output 2 (motor active current) + 24 V output Digital output (zero frequency) Unassigned Run forward Run reverse Analog input 1/ input 2 select Jog Forward Unassigned + 24 V output Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 18 4 = zero at power-up and drive disabled, Digital output (zero frequency) only change when drive is running. Unassigned Run forward Run reverse Jog Forward Unassigned + 24 V output Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 19 Analog output 1 (motor frequency) Analog output 2 (motor active current) + 24 V output Digital output (zero frequency) Unassigned Run forward Run reverse PID enable Jog Forward Unassigned + 24 V output Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 20: Emc

    Equipment which is sensitive to electrical interference operating nearby In this case it is necessary to use: • The optional external EMC filter • A shielded motor cable, with shield clamped to the grounded metal panel Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 21: Safe Torque Off (Sto)

    A shielded control cable, with shield clamped to the grounded metal panel Full instructions are given in the Drive User Guide. A full range of external EMC filters are also available for use with Unidrive M400. SAFE TORQUE OFF (STO) The SAFE TORQUE OFF function provides a means for preventing the drive from generating torque in the motor with a very high level of integrity.
  • Page 22: Optional Lcd Keypad And Display

    Figure 5-1 Unidrive M400 keypad detail (1) The Enter button is used to enter parameter view or edit mode, or to accept a parameter edit.
  • Page 23: Saving Parameters

    1244 (60 Hz settings) in Pr mm.000). 3. Either: • Press the red reset button • Carry out a drive reset through serial communications by setting Pr 10.038 to 100 Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 24: Basic Parameters (Menu 0)

    Read only (3), Status Only (4), No Access (5) Negative Logic (0) or 00.012 Input Logic Polarity Positive Logic (1) Positive Logic (1) 00.015 Jog Reference 0.00 to 300.00 Hz 1.50 Hz RW Num Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 25 Ur S (0), Ur (1), Fixed (2), 00.041 Control Mode Ur I (4) Ur Auto (3), Ur I (4), Square (5) Low Frequency Voltage 00.042 0.0 to 25.0 % 3.0 % RW Num Boost Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 26 * If this parameter is read via serial communications, it will show pole pairs. Read / Read Number Binary Text string Filtered Write only parameter parameter parameter Protected Rating Power-down default User save DE Destination copied parameter dependent save value Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 27 Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 28 Reference 1 AV.Pr AI.Pr Pad.Ref Keypad reference E. Pot 00.015 Reference Input Read-write (RW) 00.XXX terminals parameter Read-only (RO) Output 00.XXX parameter terminals The parameters are all shown in their default settings Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 29 Motor Gain Kd1 Speed 00.032 Dynamic V/f Select Motor Rpm 05.004 Power stage Maximum Switching 00.037 Frequency 05.001 Output Frequency RFC-A Current Torque Magnitude Producing 04.002 04.001 Current Magnetising Current Resistor optional Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 30: Running The Motor

    To stop the motor under ramp control, open either the run forward or Stopping run reverse terminal. If the enable terminal is opened while the motor is running, the motor will coast to a stop. Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 31: Nv Media Card Operation

    Drive User Guide for further information. The card should not be removed during data transfer, as the drive will produce a trip. If this occurs then either the transfer should be reattempted or in the case of a card to drive transfer, default parameters should be loaded. Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 32: Machine Control Studio

    Machine Control Studio software provides a flexible and intuitive environment for programming Unidrive M's new automation and motion control features. This new software offers programming for the Unidrive M400's onboard PLC. Machine Control Studio is powered by CODESYS, the leading open software for programmable machine control.
  • Page 33: Ul Listing Information

    If the drive control stage is powered from an external power supply (+24 V), the power supply must be listed or recognized to UL class 2 with appropriate fusing. • Ground connections must use UL listed closed loop (ring) terminals. Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 34: Cul Requirements For Frame Size 4

    The drive is provided with a means to accept and act upon a signal from a thermal sensor or switch imbedded in the motor or from an external protective relay. Refer to the Drive User Guide for further information. Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 35: Group Installation

    CI-485 Adaptor • AI-485 Adaptor • AI-Backup Adaptor • Remote Keypad • UL Type 1 kit • NV Media card • SI-PROFIBUS • SI-DeviceNet • SI-CANopen • SI-Ethernet • SI-EtherCAT • SI-I/O Unidrive M400 Quick Start Guide Issue Number: 5...
  • Page 36 Digital I/O Analog I/O 24 V user Analog input 1+ Frequency reference 1 Analog input 1- Digital I/O1 Zero frequency 10 V user Digital I/O 2 Digital input 3 Analog input 2 Frequency Run forward reference 2 Digital input 4 Analog output 1 Run reverse Frequency output...