Emerson Unidrive M400 User Manual page 121

Variable speed ac drive for induction motors
Hide thumbs Also See for Unidrive M400:
Table of Contents

Advertisement

Safety
Product
Mechanical
information
information
installation
Parameter
06.001 Stop Mode
06.002 Limit Switch Stop Mode
06.003 Supply Loss Mode
06.004 Start/Stop Logic Select
06.006 Injection Braking Level
06.007 Injection Braking Time
06.008 Hold Zero Frequency
06.009 Catch A Spinning Motor
06.010 Enable Conditions
06.011 Sequencer State Machine Inputs
06.012 Enable Stop Key
06.013 Enable Auxiliary Key
06.014 Disable Auto Reset On Enable
06.015 Drive Enable
06.016 Date
06.017 Time
06.018 Day Of Week
06.019 Date/Time Selector
06.020 Date Format
06.021 Time Between Filter Changes
Filter Change Required /
06.022
Change Done
06.023 Time Before Filter Change Due
06.024 Reset Energy Meter
06.025 Energy Meter: MWh
06.026 Energy Meter: kWh
06.027 Energy Cost Per kWh
06.028 Running Cost
06.029 Hardware Enable
06.030 Run Forward
06.031 Jog Forward
06.032 Run Reverse
06.033 Forward/Reverse
06.034 Run
06.035 Forward Limit Switch
06.036 Reverse Limit Switch
06.037 Jog Reverse
06.038 User Enable
06.039 Not Stop
06.040 Enable Sequencer Latching
06.041 Drive Event Flags
06.042 Control Word
06.043 Control Word Enable
06.045 Cooling Fan control
06.046 Supply Loss Hold Disable
06.047 Input Phase Loss Detection Mode
Unidrive M400 User Guide
Issue Number: 2
Electrical
Getting
Basic
Running
installation
started
parameters
the motor
Range ( )
OL
Coast (0), Ramp (1), Ramp dc I (2),
dc I (3), Timed dc I (4), Disable (5),
No Ramp (6)
Stop (0), Ramp (1)
Disable (0), Ramp Stop (1),
Ride Thru (2), Limit Stop (3)
0.0 to 150.0 %
0.0 to 25.0 s
Off (0) or On (1)
Disable (0), Enable (1), Fwd Only (2),
Rev Only (3), dc I (4)
000000000000 to 111111110111
0000000 to 1111111
Off (0) or On (1)
Disabled (0), Forward/Reverse (1),
Run Reverse (2)
Off (0) or On (1)
Off (0) or On (1)
00-00-00 to 31-12-99
00:00:00 to 23:59:59
Sunday (0), Monday (1), Tuesday (2),
Wednesday (3), Thursday (4),
Friday (5), Saturday (6)
Set (0), Powered (1), Running (2),
Acc Powered (3), Adaptor Int. (4),
Remote Keypad (5), Slot 1 (6)
Std (0), US (1)
0 to 30000 Hours
Off (0) or On (1)
0 to 30000 Hours
Off (0) or On (1)
±999.9 MWh
±99.99 kWh
0.0 to 600.0
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
Off (0) or On (1)
000000000000000 to 111111111111111
Off (0) or On (1)
Full (0), Ripple Only (1), Disabled (2)
NV Media Card
Onboard
Optimization
Operation
RFC-A
OL
0 to 6
Disabled (0)
Powered (1)
±32000
00 to 11
000000000000000
0 to 1
0 to 5
Advanced
Technical data Diagnostics
PLC
parameters
Default ( )
RFC-A
Ramp (1)
RW
Txt
Ramp (1)
RW
Txt
Disable (0)
RW
Txt
5
RW Num
100.0 %
RW Num
1.0 s
RW Num
Off (0)
RW
Bit
Disable (0)
RW
Txt
RO
Bin
RO
Bin
Off (0)
RW
Bit
RW
Txt
Off (0)
RW
Bit
On (1)
RW
Bit
RW Date ND
RW Time ND
RO
Txt
RW
Txt
Std (0)
RW
Txt
0 Hours
RW Num
RW
Bit
RO Num ND
Off (0)
RW
Bit
RO Num ND
RO Num ND
0.0
RW Num
RO Num ND
On (1)
RO
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
On (1)
RW
Bit
Off (0)
RW
Bit
Off (0)
RW
Bit
00
RW
Bin
RW
Bin
0
RW Num
2
RW Num
Off (0)
RW
Bit
Full (0)
RW
Txt
UL listing
information
Type
US
US
US
US
RA
US
US
US
US
ND
NC
PT
ND
NC
PT
US
US
US
NC
US
NC
PT
NC
PT
ND
NC
PT
US
US
US
ND
NC
NC
PT PS
NC
PT PS
NC
PT PS
US
NC
PT
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
US
NC
NC
NC
US
US
US
US
121

Hide quick links:

Advertisement

Table of Contents
loading